- The V-block can be reversed and the indication arrow ”
” show recommended cable size. Stripping distance can be changed if user moves one of the stripping blades.(AS FIG. 2)
- Stripping the coaxial jacket and inner conductor in one operation by rotating the stripper in clock wise direction 3-6 times, easy and effective.
- For stripping different materials of cable, use the built-in hex key to align the sensitive socket and adjust the blade for good results.
HT- |
For stripping RG cable |
Stripping distance |
332 |
RG-58/59/62/6/6QS/3C/4C/5C |

|
332A |
RG-/59/62/6/4C/5C |
332B |
RG-58/59/62/3C/4C |
332D |
RG-174 |
302A |
RG-59/62/6/4C/5C |
302B |
RG-58/59/62/3C/4C |
322S |
RG-8/11/213 |
Replacement blade:
HT-302 series:HT-3021, HT-312 series:3121
HT-322 serise:HT-3321, HT-322 series:3221
Special requirement is available. |